What is the minimum required number of hosts to provide data redundancy for a vSAN stretched cluster using dual-site mirroring and local protection with 1 failure - RAID-1 (Mirroring)?
Correct Answer:D
The minimum required number of hosts to provide data redundancy for a vSAN stretched cluster using dual-site mirroring and local protection with 1 failure - RAID-1 (Mirroring) is six hosts. This is because a vSAN stretched cluster requires at least three hosts per site, and each site must have enough hosts to tolerate one host failure. Therefore, the minimum configuration is three hosts per site, plus one witness host at a third site, for a total of six hosts. References: [VMware vSAN Specialist v2 EXAM 5V0- 22.23], page 14
What is the purpose of host rebuild reserve in vSAN?
Correct Answer:B
The host rebuild reserve is a feature that allows vSAN to reserve space in the cluster for vSAN to be able to repair in case of a single host failure. This reservation is set to one host worth of capacity, which means that if one host in the vSAN cluster fails and no longer contributes storage, there is still sufficient capacity remaining in the cluster to rebuild and re-protect all vSAN objects. This feature prevents the creation of new VMs or powering on VMs if such operations consume the reserved space. By default, the host rebuild reserve is disabled, but it can be enabled in the vSAN Services configuration. The other options are not related to the hostrebuild reserve. References: vSAN Capacity Management in v7.0U1; Configure Reserved Capacity
A vSAN administrator is planning to deploy a new vSAN cluster with these requirements:
Physical adapters share capacity among several traffic types Guaranteed bandwidth for vSAN during bandwidth contention Enhanced security
Which two actions should be taken to configure the new vSAN cluster to meet these requirements? (Choose two.)
Correct Answer:CE
Utilizing Network I/O Control and isolating vSAN traffic in a VLAN are the two actions that should be taken to configure the new vSAN cluster to meet the requirements. Network I/O Control allows the vSAN administrator to create network resource poolsand assign bandwidth shares or reservations to different traffic types, such as vSAN, vMotion, or management. This ensures that vSAN traffic has guaranteed bandwidth during contention and can achieve better performance and availability. Isolating vSAN traffic in a VLAN enhances the security of the cluster by preventing unauthorized access or interference from other network segments. It also simplifies the network configuration and management by reducing the broadcast domain and avoiding IP address conflicts. Creating static routes between the vSAN hosts, using IOPS Limit rules in storage policies, and enabling jumbo frames are not necessary or recommended actions for this scenario. Static routes are not required for vSAN communication, as vSAN uses multicast or unicast depending on the version and configuration. IOPS Limit rules are used to limit the IOPS allocated to an object, which can degrade the performance and latency of the application. Jumbo frames can improve the network efficiency and throughput, but they are not mandatory for vSAN and require consistent configuration across all network devices. References:
✑ Network I/O Control
✑ vSAN Network Design Guide
An administrator is deploying a new two-node vSAN cluster with a shared witness to a remote location.
Which requirement must be met?
Correct Answer:D
To deploy a new two-node vSAN cluster with a shared witness, the administrator must meet several requirements, one of which is that the ESXi hosts must have a minimum of 64 GBs of memory. This is because each host must have enough memory to run the VMs and also to support the vSAN metadata overhead. The other options are not requirements for a two-node vSAN cluster with a shared witness. The ESXi hosts do not need SSDs or NVMe for Virtual Flash File System, as they can use any supported storage devices for vSAN. The ESXi host??s controller cache and advanced features do not need to be disabled, as they can be used to improve performance and reliability. The ESXi host??s drives do not need to be configured in RAID 1, as vSAN uses its own software-defined RAID mechanism to provide Failures to Tolerate.
References: Shared Witness for 2-Node vSAN Deployments; Two-Node Cluster Requirements
A vSAN administrator needs to enable vSAN ESA.
Which two requirements need to be met? (Choose two.)
Correct Answer:BE
To enable vSAN ESA, two requirements that need to be met are: vSAN Standard license or higher, and vSAN ReadyNodes configuration. vSAN Standard license or higher is required to use vSAN ESA, as it is a feature that is only available in vSAN 8.0 or later versions. vSAN ESA is an optional, alternative architecture to vSAN OSA that is designed to process and store data with higher efficiency, scalability, and performance. vSAN ReadyNodes configuration is required to use vSAN ESA, as it is a hardware configuration that is pre-configured, tested, and certified for VMware Hyper-Converged Infrastructure Software. Each vSAN ReadyNode is optimally configured for vSAN ESA with the required amount of CPU, memory, network, and storage NVMe devices. The other options are not correct. vSAN Build Your Own configuration is not supported for vSAN ESA, as it might not meet the hardware requirements or compatibility for vSAN ESA. vSAN Witness Appliance is not required to use vSAN ESA, as it is only needed for stretched cluster or two-node cluster configurations. References: vSAN Express Storage Architecture; vSAN ReadyNode Hardware Guidance